Please read this entire manual before
installation and use of this pellet fuel-
burning room heater. Failure to follow
these instructions could result in property
damage, bodily injury, or even death.
Contact your local building or fire
of cials about restrictions and installation
inspection requirements in your area.
Save these instructions.
This manual will help you to obtain ef cient,
dependable service from the heater,
and enable you to order repair parts
correctly. Keep in a safe place for future
reference.
French version is available for download from the Breckwell website: http://www.Breckwell.com
La version française est disponible pour téléchargement à partir du site Breckwell: http://www.breckwell.com
MODEL: SPC50
OWNER’S OPERATION AND INSTALLATION MANUAL
Part No.: 852202 Rev A
Breckwell
227 Industrial Park Rd. P.O. Box 151 South Pittsburg, TN 37380
Phone (866) 606-8444 or (800) 750-2723
www.Breckwell.com
This unit is not intended to be used as a primary source of heat.
SAFETY AND EPA COMPLIANCE
Your pellet stove has been approved for installation in the USA and Canada. It may also be installed in a manufactured
or mobile home. Your stove conforms to ASTM E 1509, 2004, and Certi ed to ULC S627, 2000, and(UM) 84-HUD
Exceptional Heat, Outstanding Value
®
BRECKWELL
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - BRECKWELL

 Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could res

Pagina 2 - SAFETY PRECAUTIONS

10 COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHSMethod A. 12” (304.8 mm) Clearance to Combustible Wall Member: Using a minimum thickness 3.5” (89 m

Pagina 3 - CONGRATULATIONS!

11FACTORY BUILT CHIMNEY :When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also p

Pagina 4 - INSTALLATION

12 THERMOSTAT INSTALLATION & OPERATIONTHERMOSTAT REQUIREMENTSThe will accept a non-voltage carrying thermostat.Do not use a thermostat with a tran

Pagina 5 - FLOOR PROTECTION

13  DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE - Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fl uid, or similar

Pagina 6 - VENTILATION

14 OPERATIONDAMPER CONTROLThe damper control lever is located on the lower left side of the stove. The damper adjusts the combustion air. This control

Pagina 7 - Appliance

15  Failure to clean and maintain this unit as indicated can result in poor performance and safety hazards.  Unplug your stove’s electrical cord p

Pagina 8 - TYPE HT CHIMNEY

16 MAINTENANCEBLOWER MOTORSClean the air holes on the motors of the blowers annually. PAINTED SURFACESPainted surfaces may be wiped down with a damp c

Pagina 9 - MASONRY CHIMNEY :

17When your stove acts out of the ordinary, the fi rst reaction is to call for help. This guide may save time and money by enabling you to solve simp

Pagina 10

18 TROUBLE SHOOTING GUIDEFuel Feed Problems  Lack Of Fuel In Burnpot  To Much Fuel In BurnpotPossible Causes: Possible Remedies: (Unplug Stove First

Pagina 11 - FACTORY BUILT CHIMNEY :

19TROUBLE SHOOTING GUIDEWIRING & CONTROLSLoose wire or connector. Check all wires and connectors that connector to the auger motor, high limit s

Pagina 12 - THERMOSTAT OPERATION

2  IMPORTANT: Read this entire manual before installing and operating this product. Failure to do so may result in property damage, bodily injury,

Pagina 13 - OPERATION

20 TROUBLE SHOOTING GUIDEAir Supply / Ventilation Problems  Glass “Soot’s” Up At A Very Fast Rate,  Flame Is Lazy, Dark, And Has Black Tips ,  Af

Pagina 14

21TROUBLE SHOOTING GUIDEBLOWERThe gasket on the blower has gone bad. Inspect both gaskets on the combustion blower to make sure they are in good sha

Pagina 15 - MAINTENANCE

22 PARTS LISTPart No. Description Qty.892300 Main Stove Body (Specify Color) 140599 Legs (Specify Color) 4892301 Front Door Assembly (Specify Color) 1

Pagina 16

23WIRING DIAGRAMJ8

Pagina 19

26 is manual will help you obtain ecient, dependable service from your PELLET STOVE, and enable you to order repair parts correctly.Keep this manual

Pagina 20

27CUT HERE CUT HEREWARRANTY INFORMATION CARDName__________________________________________ Telephone #: (_____)_____________City________________

Pagina 21

28 CUT HERE CUT HEREFold Here Fold HereFold HerePLACESTAMPHEREBreckwell227 Industrial Park Rd. P.O. Box 151 South Pittsburg, TN 37380USA

Pagina 22 - PARTS LIST

3Fuel Burn Rate* (lowest setting)1 Lb/HrBurn Time (lowest setting)60 HrsHopper Capacity60 lbs. ( 27kg)HEATING SPECIFICATIONSHeight 29Width 31Depth 2

Pagina 23 - WIRING DIAGRAM

4 INSTALLATION OPTIONS  Read this entire manual before you install and use your pellet stove. Failure to follow instructions may result in property

Pagina 24

5FLOOR PROTECTIONThis heater must have a non-combustible fl oor protector (ember protection) installed beneath it, if the fl oor is of combustible mat

Pagina 25

6 NOTE: DIMENSIONS TO YOUR STOVES INLET/EXHAUST PIPES ARE APPROXIMATE AND MAY VARY DEPENDING ON YOUR INSTALLATION.TYPICAL FRESH AIR TERMINATIONOUTSID

Pagina 26

7CHIMNEY CONNECTOR (STOVE PIPE)Your chimney connector and chimney must have a diameter of 4” - 6”. If this is not the case, we recommend you contact

Pagina 27 - WARRANTY INFORMATION CARD

8 PELLET VENT TYPEA UL listed 4-inch or 6-inch type “PL” pellet vent exhaust system may be used for installation and attached to the pipe connector pr

Pagina 28

9MASONRY CHIMNEY :Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspecte